FM certified fire pipe is a certification standard for fire pipe provided by FM Global in the United States. This standard fire hose is extremely demanding on the performance of building materials and systems. Pandapipe’s FM certified fire pipes have been carefully designed to be widely used due to their excellent resistance to high temperatures, corrosion and pressure. Designed for fire protection, this tube is stable and reliable even under the most challenging fire conditions. Provide reliable fire protection for your project.

FM Approved Fire Pipe Specification

The FM Approved Fire Pipe manufactured by Pandapipe meets the highest standards of quality and safety. Adopt strict manufacturing process, comprehensive specifications for you to choose. Made of top grade steel. There are also surface coating, combined methods, pipe packing and other processing services. Make sure the product you get is of high quality and performance.

StandardEN10217, EN10216, ASTM A53, ASTM A795, ASTM A135, ASTM A106
ProcedureERW, SMLS
Dimensions33.4mm – 355.6mm
1″ – 14″
DN25 – DN350
Thickness1.65mm – 25.4mm
SCH10, SCH10, SCH30, SCH40
Unit Length1.5 – 12 mtrs
Steel GradeDepending on the implementation criteria chosen by the customer, see other home page standards for details.
Surface CoatingBlack, Red, Primer, Hot Dip Galvanizing, FBE coating
End TypeSquare cut, Bevelled, Grooved
Joint MethodFitting, Flange, Coupling, Clamp, Pipe Shoulder, Welding
Pipe PackingIn bundles, Plastic wrap

FM Approved Fire Pipe Dimension Table

Pandapipe offers FM Approved Fire Pipe in a comprehensive range of sizes. Nominal pipe sizes from 1 to 6 inches. There are various standards such as Schedule 10 and Schedule 40. Outer diameter from 33.4mm to 168.3 mm. Customization services are also available to ensure that you can get any size you want.

Product Listing Country Nominal Pipe Size, inch Rated Working Pressure, psi Rated Working Pressure, kPa Certification Type
Schedule 40 a, b, d, e, g, m, n, p China 1, 1- 1/4, 1- 1/2, 2 175 1205 FM Approved
Schedule 40 a, b, d, e, m, n, p China 1, 1- 1/4, 1- 1/2, 2, 2- 1/2, 3, 3- 1/2, 4, 5, 6 300 2070 FM Approved
  • Notes:           a – FM Approved for use with FM Approved pipe couplings on rolled or cut grooves.
  • b – FM Approved for use with FM Approved pipe fittings when threaded.
  • d – When hot dip galvanized by factory, the sprinkler pipe is FM Approved for dry pipe systems.
  • e – Any FM Approved pipe coupling or fitting suitable for use with Schedule 10 pipe may be used with this product at the lower rated pressure of the pipe or the fitting.
  • g – FM Approved for use with plain-end fittings.
  • m – FM Approved for use in all steel sprinkler systems composed of uncoated or coated steel pipe.
  • n – FM Approved for use in hybrid sprinkler systems composed of uncoated steel and plastic piping.
  • p – Manufactured out of ASTM A53 or ASTM A795 Grade B steel.
Nominal Pipe Size Outside Diameter Nominal Wall Thickness Schedule
NPS DN mm SCH 10 SCH 40
1 25 33.4 2.77 3.38
1 1/4 32 42.2 2.77 3.56
1 1/2 40 48.3 2.77 3.68
2 50 60.3 2.77 3.91
2 1/2 65 73 3.05 5.16
3 80 88.9 3.05 5.49
3 1/2 90 101.6 3.05 5.74
4 100 114.3 3.05 6.02
5 125 141.3 3.40 6.55
6 150 168.3 3.40 7.11
Solar Tracker Torque Tube

Chemical Requirements of FM Approved Fire Pipe

The FM Approved Fire Pipe produced by Pandapipe strictly complies with the chemical composition requirements of the FM standard. The content and proportion of carbon, manganese, phosphorus, sulfur, silicon and other elements in the pipeline are controlled in the best way. To ensure that the pipes manufactured have the best performance and quality.

ElementsGrade AGrade BGrade C
Carbon max. %0.250.30.35
Manganese %0.27 to 0.930.29 to 1.060.29 to 1.06
Phosphorous, max. %0.0250.0250.025
Sulfur, max. %0.0250.0250.025
Silicon, min. %0.10.10.1

Mechanical Requirements of FM Approved Fire Pipe

The FM Approved Fire Pipe manufactured by Pandapipe meets the stringent mechanical requirements of the FM standard. The mechanical properties such as yield strength, elongation and tensile strength are strictly controlled to ensure that the pipe can withstand high temperature and high pressure environment and maintain the best performance.

 Grade AGrade BGrade C
Tensile Strength, min., psi48,00060,00070,000
Yield Strength, min., psi30,00035,00040,000

Application of FM Approved Fire Pipe

  • Food processing: since water and other chemicals in food processing and production will corrode the piping system, the corrosion resistance of FM Approved Fire Pipe can effectively prevent fire and corrosion.
  • Residential construction: FM Approved Fire Pipe Security in high-rise residences and large residential complexes ensures the safety of residents.
  • Commercial buildings: FM Approved Fire Pipe is often used in hotels, shopping malls and office buildings. Provide stable performance assurance in complex building structures.
  • Pharmaceutical industry: FM Approved Fire Pipe, with its excellent resistance to high pressure, provides a favorable guarantee for the safety of the pharmaceutical production environment.

Related Products

Our Advantages

  1. Over 25 years of experience in pipeline production and installation.
  2. Comprehensive inspection equipment.
  3. Independent product serial numbers for traceability.
  4. Advanced production equipment – Seamer high-frequency welding machine from the United States.
  5. Complete qualifications – API 5L/API 5CT/FM/UL fire pipe certification, etc.
  6. Wide range of products – independently developed solar torque tubes, highly favored in the European market.
  7. Customers spread across the globe.
  8. Excellent after-sales service and sense of responsibility.
en_USEnglish

CONTACT US