All pipes mentioned in this article are sold by PANDAPIPE.
What is Outer Diameter
Outer Diameter of Steel Pipe Standard Specification Chart
Steel Pipe Outer Diameter Chart (OD MM, Inch)
The unit for tube outer diameter is millimeters or inches. In the steel pipe outer diameter chart below, you can clearly see the unit conversions between pipe outer diameter, DN, and NPS.
For example, DN15=NPS 1/2″=Outer Diameter 21.3 mm=0.84 inch
Steel Pipe Outer Diameter Chart
Nominal Size (DN) | NPS (Inch) | Outer Diameter (mm) | Outer Diameter (inch) |
DN15 | 1/2″ | 21.3 mm | 0.84 in |
DN20 | 3/4″ | 26.9 mm | 1.05 in |
DN25 | 1″ | 33.7 mm | 1.33 in |
DN32 | 1 1/4″ | 42.4 mm | 1.67 in |
DN40 | 1 1/2″ | 48.3 mm | 1.90 in |
DN50 | 2″ | 60.3 mm | 2.38 in |
DN65 | 2 1/2″ | 76.1 mm | 3.00 in |
DN80 | 3″ | 88.9 mm | 3.50 in |
DN100 | 4″ | 114.3 mm | 4.50 in |
DN125 | 5″ | 141.3 mm | 5.56 in |
DN150 | 6″ | 168.3 mm | 6.63 in |
DN200 | 8″ | 219.1 mm | 8.63 in |
DN250 | 10″ | 273.0 mm | 10.75 in |
DN300 | 12″ | 323.9 mm | 12.75 in |
DN350 | 14″ | 355.6 mm | 14.00 in |
DN400 | 16″ | 406.4 mm | 16.00 in |
DN450 | 18″ | 457.2 mm | 18.00 in |
DN500 | 20″ | 508.0 mm | 20.00 in |
Outer Diameter Formula
Outer Diameter Formula:
OD = ID + (2 × Wall Thickness)
Click the link below to view detailed information about Nominal Pipe Size (NPS).
Outer and Inner Diameter
Outer Diameter vs Inner Diameter Chart
| Item | OD | ID |
|---|---|---|
| Definition | Outside measurement | Inside measurement |
| Usage | Pipe selection | Flow calculation |
| Fixed or Variable | Usually fixed | Changes with wall thickness |
How Does Out Diameter Affect Pipe Performance
How to Select the Outer Diameter/ Diameter Outside of Steel Pipes
- Pressure: For high-pressure systems, both outside diameter and wall thickness must provide sufficient safety margins.
- Medium: For highly corrosive substances, consider corrosion resistance and long-term stability;
- Site conditions: In confined spaces, an excessively large outer diameter may not fit at all.
Why Does a Non-Standard Pipe OD Cost More?
A non-standard outer diameter normally costs more than a standard OD, even when the steel grade and wall thickness are the same. This is because the mill may need dedicated forming rolls or molds, new production-line settings, and raw-material widths prepared specifically for that diameter.
Inspection can also require matching fixtures or adjustments to the measuring equipment. Because fewer orders share these setup costs, a custom OD usually has a higher minimum order quantity than a standard pipe size.
Before requesting a quotation, buyers should provide the required OD, wall thickness, length, quantity, applicable standard, end-use, and dimensional tolerance. If the quantity is small, selecting the nearest standard OD may significantly reduce tooling, production, and inspection costs.
Steel Pipe Specifications Quality Control Standards
Which OD Measurements Matter for Large-Diameter Welded Pipe?
For SSAW and LSAW pipes, checking only the average OD is not enough. Pipe-end geometry directly affects field fit-up and the internal misalignment, or Hi-Lo, between two pipe ends.
| Inspection item | What it shows | Common risk if ignored |
|---|---|---|
| Average OD | Overall nominal pipe size calculated from circumference | A pipe may pass this check while still being oval |
| Local OD | Diameters measured at several positions on the same cross-section | Local flattening or bulging may prevent proper fit-up |
| Ovality | Difference between the maximum and minimum diameters | Excessive ovality can cause Hi-Lo and field welding rework |
Ovality formula:
Ovality = (Dmax − Dmin) ÷ Dnom × 100%
In our inspection experience, the recommended priority for large-diameter welded pipe is:
Pipe-end ovality → pipe-end local OD → average OD
At the pipe end, inspectors should measure the diameter in at least four directions and record both Dmax and Dmin. Using only a circumference tape may confirm the average OD, but it cannot identify an oval cross-section.
Buyers should also check end squareness, bevel dimensions, local wall thickness around the pipe end, and full-length straightness. The acceptance limits and measurement locations must follow the applicable standard, purchase specification, and agreed inspection plan.
Related links:
- Schedule 10 Pipe- Dimensions, Thickness, Weight and Pressure Rating Guide
- Schedule 20 Pipe Chart- Dimensions, Pressure, Manufacturer
- Schedule 40 Pipe Dimensions Guide
- Schedule 40 vs 80 Steel Pipe: A Comprehensive Comparison and Engineering Selection Guide
- Steel Pipe Inspection: 7 Checks Before Approving Shipment