AS/NZS 1163 C350L0 combines a minimum yield strength of 350 MPa with specified impact properties at 0°C. Buyers should also verify section dimensions, ACRS scope, material traceability and test documentation before ordering.
AS/NZS 1163 C350L0 is widely specified for structural hollow sections used in Australian construction, infrastructure and fabrication projects. For buyers, however, the grade name is only the starting point.
Before ordering, you still need to confirm the section type, dimensions, impact requirements, tolerances and certification. If ACRS certification is required, the ordered product should also be checked against the certificate scope.
What Does AS/NZS 1163 C350L0 Mean?
AS/NZS 1163 covers cold-formed structural steel hollow sections. The C350L0 designation tells you three important things:
- C — cold-formed structural hollow section
- 350 — minimum yield strength of 350 MPa
- L0 — specified impact properties at 0°C
C350L0 has a minimum tensile strength of 430 MPa. The L0 designation is especially important because it separates impact-tested material from ordinary C350.
If your project drawing specifies C350L0, do not approve C350 as a substitute based only on the same yield strength.
Where Is C350L0 Steel Used?
C350L0 is used where structural strength and verified impact performance are required. Typical applications include building frames, columns, trusses, bracing, structural supports and fabricated steel structures.
It is supplied in three common forms:
- CHS — Circular Hollow Section
- SHS — Square Hollow Section
- RHS — Rectangular Hollow Section
The final grade and section should follow the structural drawing or project specification rather than being selected on price alone.
AS/NZS 1163 C350L0 Mechanical and Impact Requirements
For procurement, these are the main properties to check:
| Property | C350L0 Requirement |
|---|---|
| Minimum Yield Strength | 350 MPa |
| Minimum Tensile Strength | 430 MPa |
| Impact Test | Charpy V-notch |
| Impact Test Temperature | 0°C |
| Product Forms | CHS, SHS, RHS |
AS/NZS 1163 hollow sections also specifies elongation according to section geometry. For C350/C350L0, the required minimum elongation varies with the diameter-to-thickness or width-to-thickness ratio.
For L0 grades, the standard specifies Charpy V-notch testing at 0°C. For a full-size 10 × 10 mm specimen, the minimum absorbed energy is 27 J average for three tests and 20 J for an individual test.
This is why checking only yield and tensile strength is not enough when the project calls for C350L0.
C350 vs C350L0: Can You Substitute Them?
Not automatically.
| Requirement | C350 | C350L0 |
|---|---|---|
| Minimum Yield Strength | 350 MPa | 350 MPa |
| Minimum Tensile Strength | 430 MPa | 430 MPa |
| L0 Impact Requirement | No | Yes, at 0°C |
The strength values may look identical, but the impact requirement is different.
If the specification states C350L0, ask the supplier to confirm the grade and relevant impact-test results before approving material for the project.
If you are still deciding between strength grades, see our AS/NZS 1163 C250 vs C350 comparison to understand the differences in strength, specification, and grade selection.
How to Specify C350L0 in Your RFQ
Writing only “AS/NZS 1163 C350L0” is not enough for an accurate quotation.
A useful RFQ should include:
| RFQ Item | Example |
|---|---|
| Standard / Grade | AS/NZS 1163 C350L0 |
| Section | RHS |
| Size | 150 × 100 mm |
| Wall Thickness | 6 mm |
| Length | 12 m |
| Surface | Black / Galvanized |
| Quantity | 50 MT |
| Certification | ACRS, if required |
If you have a BOM or project specification, send it with the RFQ. This allows the manufacturer to check the requested sizes and technical requirements before pricing.
Confirm the Actual OD for CHS Before Quotation
For CHS inquiries from Australia and New Zealand, we sometimes receive a nominal pipe size instead of the actual outside diameter required for the structural hollow section. Before quotation, we confirm the OD, wall thickness and applicable AS/NZS 1163 size with the buyer rather than pricing directly from the nominal description. This check matters because using the wrong diameter can affect fabrication fit-up, connection details and the final project BOM.
Three Checks Before Ordering C350L0
Check the ACRS Certificate Scope
Do not stop at asking, “Do you have ACRS?”
An ACRS certificate has a defined product scope. If certification is required by your project, check whether the grade, CHS/SHS/RHS product and required dimensional range are covered by the supplier’s current certificate.
In actual project inquiries, “Do you have ACRS?” is usually only the first question. Buyers and engineers may then check the certificate scope against the exact order. Before confirming compliance, we normally match four items:
| ACRS Scope Check | What to Match With the RFQ |
|---|---|
| Standard | AS/NZS 1163 |
| Product type | CHS, SHS or RHS |
| Grade | C250, C350, C350L0 or other specified grade |
| Size range | Required outside dimensions and wall thickness |
A valid ACRS certificate should not be treated as automatic coverage for every hollow section a factory can manufacture. The ordered product needs to fall within the applicable certificate scope.
Check MTC and Product Traceability
Review the Material Test Certificate against the supplied steel.
Grade, dimensions, heat or batch identification and applicable test results should correspond with the material. Clear product marking also helps maintain traceability from the hollow section back to its inspection records.
Check Dimensions and Tolerances
AS/NZS 1163 controls more than material strength. Dimensional tolerances also apply to wall thickness, external dimensions, straightness, twist and other characteristics.
Do not judge compliance simply because an actual wall-thickness reading differs slightly from the nominal value. It should be evaluated against the applicable tolerance in the standard.
Request an AS/NZS 1163 C350L0 Quote
PANDAPIPE supplies structural steel pipe and hollow sections for international B2B projects. For AS/NZS 1163 C350L0, we can review your CHS, SHS or RHS requirements against the requested dimensions, grade and certification requirements before quotation.
Send PANDAPIPE your BOM, drawing or steel list for an AS/NZS 1163 C350L0 quotation.
FAQs:
1. What does C350L0 mean?
C indicates cold-formed hollow section, 350 indicates a 350 MPa minimum yield strength, and L0 identifies specified impact properties at 0°C.
2. Is C350 the same as C350L0?
No. Their minimum yield and tensile strengths are the same, but C350L0 includes the L0 impact requirement.
3. What is the tensile strength of C350L0?
The minimum tensile strength is 430 MPa.
4. What is the yield strength of C350L0?
The minimum yield strength is 350 MPa.
5. What is the C350L0 impact test temperature?
L0 grades are impact tested at 0°C according to AS/NZS 1163 requirements.
6. Is C350L0 available in CHS, SHS and RHS?
Yes. C350L0 is specified for circular, square and rectangular structural hollow sections.
7. Does ACRS certification cover every C350L0 size?
Not necessarily. Buyers should verify the supplier’s current certificate scope against the required product and dimensional range.
8. What information is needed for a C350L0 quotation?
Provide the standard, grade, section type, dimensions, wall thickness, length, quantity, finish and certification requirements.